M30 Mix Design Calculator | 30 MPa Concrete 2026 β€” IS 10262:2019 Absolute Volume Method with IS 456 Compliance

M30 Mix Design Calculator

30 MPa Concrete | IS 10262:2019 Absolute Volume Method β€” Calculate Complete Mix Proportions, IS 456 Compliance Checks, Step-by-Step Workings & Batch Quantities for Any Pour Volume

IS 10262:2019IS 456:2000 fck = 30 MPafcm = 38.25 MPa Absolute Volume MethodStep-by-Step IS 456 Compliance

πŸ—οΈ M30 Concrete β€” Overview & Design Basis

IS 10262:2019 β€” Primary Method IS 456:2000 Table 5 β€” Exposure Limits IS 9103:1999 β€” Admixtures IS 383:2016 β€” Aggregates

M30 is one of the most widely specified structural concrete grades in India β€” the minimum grade for Severe exposure class per IS 456:2000 Table 5, and the workhorse of commercial buildings, bridges, and infrastructure projects. This calculator implements the complete IS 10262:2019 Absolute Volume Method step by step, showing every formula and every calculated intermediate value β€” so results can be independently verified.

Enter your project-specific material properties below. The calculator uses IS 10262:2019 Table 2 for water content, the Bogue-correlation w/c relationship for target mean strength, and calculates FA/CA split based on IS 383 zone and fineness modulus adjustment.

M30 Grade β€” Key Design Parameters

Characteristic Strength fck: 30 MPa (28-day cube)
Standard Deviation S: 5.0 MPa (IS 10262 Table 1)
Target Mean Strength fcm: 30 + 1.65 Γ— 5.0 = 38.25 MPa
Max w/c (Moderate exp.): 0.50 per IS 456 Table 5
Min Cement (Moderate): 300 kg/mΒ³ per IS 456 Table 5
Min Grade IS 456 Table 5: M25 (Moderate), M30 (Severe)
IS 456 Minimum MSA: IS 456 Cl. 5.3.1 (cover / bar spacing)

βš™οΈ Mix Design Inputs β€” Enter Your Project Material Data

Mix Design Basis

Cement & Cementitious Materials

OPC 53: 3.15 | PPC: 2.89 | PSC: 2.90
FA: 15–35% | GGBS: 20–65% | SF: 5–15%

Fine & Coarse Aggregate

River Sand: 2.60–2.68 | M-Sand: 2.62–2.70
Calculated from sieve analysis β€” IS 2386 Pt.1
Granite: 2.63–2.70 | Basalt: 2.70–3.00
Granite: 0.2–1.5% | RCA: 3–8.5%

Admixture & Air

Non-AE vibrated concrete: 1.5–2.5%

Ready to Calculate

Enter your material properties above and click Calculate M30 Mix Design. The calculator will show complete IS 10262:2019 proportions, step-by-step workings, IS 456 compliance check, and batch quantities for your specified pour volume.

πŸ“ Theoretical Background β€” IS 10262:2019 Method for M30

The following fixed parameters apply to all M30 designs per IS 10262:2019 and IS 456:2000, regardless of material inputs:

1
Target Mean Strength (fcm)

IS 10262:2019 Cl. 5.1 β€” fcm must account for production variability (SD = 5.0 MPa for M25–M35 per Table 1) so that only 5% of results fall below fck.

fcm = fck + k Γ— S
= 30 + 1.65 Γ— 5.0
= 30 + 8.25
= 38.25 MPa (target mean strength)

2
Water-Cement Ratio Selection

Lower of: strength-based w/c from Abrams' Law correlation (OPC 53: w/c β‰ˆ 0.46 for fcm = 38.25 MPa) AND IS 456 Table 5 maximum for exposure class.

Strength-based w/c (OPC 53, fcm 38.25 MPa):
w/c β‰ˆ 0.46

IS 456 Table 5 maximum w/c by exposure:
Moderate: 0.50 | Severe: 0.45 | V.Severe: 0.40

Design w/c = min(0.46, IS 456 max)

3
Free Water Content (IS 10262 Table 2)

Water content is read from IS 10262:2019 Table 2 by slump and MSA (crushed aggregate basis), then adjusted for aggregate shape and SP water reduction.

Base water (crushed, 20mm MSA, 100mm slump) = 202 L/mΒ³

Adjustment for M-Sand FA: +5 to +10 L/mΒ³
SP water reduction (PCE 25%): Γ— 0.75

Effective water = 202 Γ— 0.75 β‰ˆ 152 L/mΒ³ (approx.)

4
Cement Content

Cement = Water / w/c. Check against IS 456 Table 5 minimum (300 kg/mΒ³ for Moderate) and maximum (550 kg/mΒ³, IS 456 Cl. 8.2.5).

C = W / (w/c) [kg/mΒ³]
= 152 / 0.46 β‰ˆ 330 kg/mΒ³

Check: 330 β‰₯ 300 (IS 456 min) βœ…
330 ≀ 550 (IS 456 max) βœ…

5
Absolute Volume β€” Aggregate

V_agg = 1.000 βˆ’ V_cement βˆ’ V_SCM βˆ’ V_water βˆ’ V_air βˆ’ V_admix

V_cem = C / (Sg_cem Γ— 1000)
V_water= W / 1000
V_air = Air% / 100
V_SP = SP volume (L/mΒ³) / 1000
V_agg = 1.000 βˆ’ sum of above

6
FA/CA Split (IS 10262 Cl. 5.3)

Base FA% from IS 10262 Zone table; adjusted by FM deviation from 2.60 (Β±1.5% per 0.1 FM change).

Zone II (20mm MSA) base FA% = 40%
FM adjustment (FM 2.7 βˆ’ 2.6 = +0.1):
Ξ”FA% = βˆ’1.5% per +0.1 FM = βˆ’1.5%
Adjusted FA% = 40 βˆ’ 1.5 = 38.5%

FA mass = V_agg Γ— 0.385 Γ— Sg_FA Γ— 1000
CA mass = V_agg Γ— 0.615 Γ— Sg_CA Γ— 1000

πŸ“š IS 456 M30 Requirements Quick Reference 2026

← Scroll
Exposure ClassMin GradeMax w/cMin Cement (kg/mΒ³)Min Cover (mm)M30 Suitability
MildM200.6030020Over-specified
ModerateM250.5030030βœ… Fully Compliant
SevereM300.4532045βœ… Minimum Code Grade
Very SevereM350.4036050❌ M30 Not Permitted
ExtremeM400.3538075❌ M30 Not Permitted

IS 10262:2019 vs IS 10262:2009 β€” Key Changes for M30

The 2019 First Revision of IS 10262 updated Table 2 water content values (slightly revised for specific slump-MSA combinations), expanded Annexure B coverage of SCMs, and provided more explicit guidance on admixture water correction. For M30, the key practical change is the formal recognition of PCE SP water reduction in the calculation procedure, enabling cement-efficient M30 designs (350–380 kg/mΒ³ OPC 53 range) that were previously harder to justify without explicit standard coverage. All calculations in this page implement IS 10262:2019 exclusively.