Sieve Analysis Tool 2026 β IS 383:2016 Zone Classification, Fineness Modulus, Gradation Curve & IS 10262:2019 Mix Design Guidance for Fine & Coarse Aggregates
Start Sieve AnalysisSieve analysis (particle size distribution test) is the most fundamental aggregate quality test in concrete technology. The gradation of your fine aggregate determines its IS 383:2016 zone classification, which directly governs the recommended FA:CA ratio in IS 10262:2019 Annex A. A zone classification error in mix design β for example, using Zone II defaults when the actual sand is Zone III or Zone IV β can increase water demand by 10β25 kg/mΒ³, raise cement content by 15β35 kg/mΒ³, and reduce durability. This calculator performs a complete IS 2386 Part 1 sieve analysis, classifies the aggregate per IS 383:2016, and provides mix design guidance for IS 10262:2019.
Enter the mass retained on each sieve in grams. The total sample mass is typically 500β1000g for fine aggregate per IS 2386 Part 1. Enter 0 for any sieve with no retained material.
| IS Sieve Size | Mass Retained (g) | % Retained | Cum. % Retained | Cum. % Passing | Zone I Limit | Zone II Limit | Zone III Limit | Zone IV Limit |
|---|
| Sieve | Mass Ret. (g) | % Retained | Cum. % Ret. | Cum. % Passing | Zone I | Zone II | Zone III | Zone IV |
|---|
Select your coarse aggregate nominal maximum size and enter mass retained on each relevant IS sieve. Compliance is checked against IS 383:2016 single-size grading limits.
| IS Sieve Size | Mass Retained (g) | % Retained | Cum. % Retained | Cum. % Passing | IS 383 Min% | IS 383 Max% | Compliance |
|---|
β Scroll horizontally to view all columns β
| IS Sieve | Zone I (% Passing) | Zone II (% Passing) Preferred | Zone III (% Passing) | Zone IV (% Passing) | Combined Grading | M-Sand Zone II |
|---|---|---|---|---|---|---|
| 10.00 mm | 100 | 100 | 100 | 100 | 100 | 100 |
| 4.75 mm | 90 β 100 | 90 β 100 | 90 β 100 | 95 β 100 | 95 β 100 | 90 β 100 |
| 2.36 mm | 60 β 95 | 75 β 100 | 85 β 100 | 95 β 100 | 80 β 100 | 75 β 100 |
| 1.18 mm | 30 β 70 | 55 β 90 | 75 β 100 | 90 β 100 | 70 β 100 | 55 β 90 |
| 600 Β΅m | 15 β 34 | 35 β 59 | 60 β 79 | 80 β 100 | 55 β 100 | 35 β 65 |
| 300 Β΅m | 5 β 20 | 8 β 30 | 12 β 40 | 15 β 50 | 10 β 50 | 10 β 35 |
| 150 Β΅m | 0 β 10 | 0 β 10 | 0 β 10 | 0 β 15 | 0 β 15 | 0 β 20 |
| FM Range | 3.5 β 4.0 | 2.9 β 3.5 | 2.3 β 2.9 | 1.6 β 2.3 | 2.6 β 3.5 | 2.9 β 3.5 |
| Zone | FM Range | Character | Water Demand vs Zone II | IS 10262 FA% Adjustment vs Zone II Baseline | Grades Suitable | Best For |
|---|---|---|---|---|---|---|
| Zone I | 3.5 β 4.0 | Coarse sand | β5 to β10 kg/mΒ³ | +4 to +6% more FA | M15 β M45 | Mass concrete; low water requirement |
| Zone II Preferred | 2.9 β 3.5 | Standard sand | Baseline | IS 10262 Annex A default | M15 β M70 | All structural concrete |
| Zone III | 2.3 β 2.9 | Medium fine | +5 to +10 kg/mΒ³ | β4 to β6% less FA | M15 β M45 | Pump mixes; better finish |
| Zone IV | 1.6 β 2.3 | Very fine | +15 to +25 kg/mΒ³ | β8 to β10% less FA | M15 β M30 only | Smooth finishes; NOT M35+ |