Sieve analysis (particle size distribution test) is the most fundamental aggregate quality test in concrete technology. The gradation of your fine aggregate determines its IS 383:2016 zone classification, which directly governs the recommended FA:CA ratio in IS 10262:2019 Annex A. A zone classification error in mix design β€” for example, using Zone II defaults when the actual sand is Zone III or Zone IV β€” can increase water demand by 10–25 kg/mΒ³, raise cement content by 15–35 kg/mΒ³, and reduce durability. This calculator performs a complete IS 2386 Part 1 sieve analysis, classifies the aggregate per IS 383:2016, and provides mix design guidance for IS 10262:2019.

How This Calculator Works

  • Fine Aggregate Tab: Enter the mass retained on each of the 7 IS 383 standard sieves (4.75mm, 2.36mm, 1.18mm, 600Β΅m, 300Β΅m, 150Β΅m, Pan). The calculator computes % retained, cumulative % retained, cumulative % passing, fineness modulus, and classifies the sand into Zone I, II, III, or IV per IS 383:2016. The gradation curve is plotted against all four zone boundary envelopes
  • Coarse Aggregate Tab: Enter mass retained on the relevant IS sieves for your nominated CA size (10mm, 20mm, or 40mm). The calculator verifies compliance with IS 383:2016 coarse aggregate grading limits
  • IS 10262 Guidance: Based on the classified zone and your entered w/c range, the calculator outputs the recommended FA% for your mix design per IS 10262:2019 Annex A Table A-1
  • Sample Presets: Load pre-filled example data for each zone or aggregate type to see what typical results look like before entering your own data

Sieve Analysis Calculator – IS 383:2016 & IS 2386 Part 1

Enter the mass retained on each sieve in grams. The total sample mass is typically 500–1000g for fine aggregate per IS 2386 Part 1. Enter 0 for any sieve with no retained material.

Load Example:
IS Sieve Size Mass Retained (g) % Retained Cum. % Retained Cum. % Passing Zone I Limit Zone II Limit Zone III Limit Zone IV Limit
Total Sample Mass
β€”
grams
Fineness Modulus
β€”
FM
IS 383:2016 Zone
β€”
 
Pan Loss
β€”
%

Gradation Curve – Particle Size Distribution

IS 10262:2019 Mix Design Guidance

Full Sieve Analysis Results

Sieve Mass Ret. (g) % Retained Cum. % Ret. Cum. % Passing Zone I Zone II Zone III Zone IV

Select your coarse aggregate nominal maximum size and enter mass retained on each relevant IS sieve. Compliance is checked against IS 383:2016 single-size grading limits.

IS Sieve Size Mass Retained (g) % Retained Cum. % Retained Cum. % Passing IS 383 Min% IS 383 Max% Compliance
Total Sample Mass
β€”
grams
Nominal Max Size
β€”
mm
Compliance
β€”
 
Sieves Checked
β€”
sieves

IS 383:2016 Fine Aggregate Grading Zones – Reference Chart & Zone Classification Guide

← Scroll horizontally to view all columns β†’

IS Sieve Zone I (% Passing) Zone II (% Passing) Preferred Zone III (% Passing) Zone IV (% Passing) Combined Grading M-Sand Zone II
10.00 mm100100100100100100
4.75 mm90 – 10090 – 10090 – 10095 – 10095 – 10090 – 100
2.36 mm60 – 9575 – 10085 – 10095 – 10080 – 10075 – 100
1.18 mm30 – 7055 – 9075 – 10090 – 10070 – 10055 – 90
600 Β΅m15 – 3435 – 5960 – 7980 – 10055 – 10035 – 65
300 Β΅m5 – 208 – 3012 – 4015 – 5010 – 5010 – 35
150 Β΅m0 – 100 – 100 – 100 – 150 – 150 – 20
FM Range3.5 – 4.02.9 – 3.52.3 – 2.91.6 – 2.32.6 – 3.52.9 – 3.5
Zone FM Range Character Water Demand vs Zone II IS 10262 FA% Adjustment vs Zone II Baseline Grades Suitable Best For
Zone I 3.5 – 4.0 Coarse sand βˆ’5 to βˆ’10 kg/mΒ³ +4 to +6% more FA M15 – M45 Mass concrete; low water requirement
Zone II Preferred 2.9 – 3.5 Standard sand Baseline IS 10262 Annex A default M15 – M70 All structural concrete
Zone III 2.3 – 2.9 Medium fine +5 to +10 kg/mΒ³ βˆ’4 to βˆ’6% less FA M15 – M45 Pump mixes; better finish
Zone IV 1.6 – 2.3 Very fine +15 to +25 kg/mΒ³ βˆ’8 to βˆ’10% less FA M15 – M30 only Smooth finishes; NOT M35+

FM Change Adjustment Rule – IS 10262:2019 Annex A

  • Β±0.1 FM change from design FM: Monitor; no immediate action needed
  • Β±0.2 FM change: Adjust FA:CA ratio by Β±3% β€” coarser sand needs more FA, finer needs less FA
  • Β±0.3 FM change or zone crossing: Formal mix design revision required; trial mix before production continues
  • Weekly FM monitoring: Best practice and CPWD requirement for all M30+ concrete

How to Conduct a Sieve Analysis – IS 2386 Part 1:1963 Step-by-Step Procedure 2026

Equipment Required

  • IS standard test sieves: 10mm, 4.75mm, 2.36mm, 1.18mm, 600Β΅m, 300Β΅m, 150Β΅m (and pan) for fine aggregate
  • Balance: Accurate to 0.1g for fine aggregate; accurate to 1g for coarse aggregate
  • Sieve shaker (mechanical or manual) with lid and pan
  • Oven at 105Β°C Β± 5Β°C for drying
  • Dry brushes for cleaning sieves between tests

Step-by-Step Procedure (IS 2386 Part 1:1963)

  1. Sample Selection: Collect representative sample using quartering method. Dry at 105Β°C to constant mass. Minimum sample: 500g for fine aggregate (IS 2386); 5 kg for 20mm CA; 10 kg for 40mm CA
  2. Weigh Sample: Weigh the dry sample to 0.1g accuracy. Record as W_total (g)
  3. Stack Sieves: Arrange sieves in descending order (largest at top). Place pan at the bottom. Stack order for FA: 10mm β†’ 4.75mm β†’ 2.36mm β†’ 1.18mm β†’ 600Β΅m β†’ 300Β΅m β†’ 150Β΅m β†’ Pan
  4. Pour Sample: Pour the dry sample onto the top sieve. Place lid
  5. Shake: Mechanical shaker: 10–15 minutes. Manual shaking: each sieve shaken individually for 2 minutes with circular, rocking motion until not more than 1% passes in 1 minute of additional shaking
  6. Weigh Retained: Weigh the material retained on each sieve individually. Record all masses to 0.1g
  7. Check Loss: Sum all retained masses + pan. Difference from original mass = loss. Acceptable loss: ≀ 1% of original sample mass. If loss > 1%, repeat the test
  8. Calculate: Enter masses in the calculator above to compute % retained, cumulative % retained, cumulative % passing, fineness modulus, and zone classification automatically

Common Errors in Sieve Analysis – 2026 Site Advisory

  • Wet sample: Always dry to constant mass before sieving. Damp sand clumps and gives false high retained values on finer sieves β€” significantly overestimating FM
  • Overloading sieves: IS 2386 Part 1 limits mass on each sieve to prevent blocking. Rule of thumb: mass per sieve (g) ≀ 200 Γ— (sieve aperture in mm). Overloaded sieves give false coarser results
  • Loss > 1%: Material between or below sieves invalidates the test. Inspect sieve seals; ensure pan is fully seated; use clean sieves with no blocked apertures
  • Not cleaning sieves: Residual material from previous tests in sieve apertures shifts results. Clean each sieve with a soft brush before use β€” never use wire brushes or wash with water during a test sequence
  • Wrong quartering: Using a non-representative sample (e.g. only surface material from stockpile) gives results unrepresentative of the full aggregate population. Always use the cone-and-quarter or riffle-box method
  • FM calculation error: The 10mm sieve IS NOT included in the FM calculation for fine aggregate. Only include the 6 standard sieves: 4.75mm, 2.36mm, 1.18mm, 600Β΅m, 300Β΅m, and 150Β΅m